Clinical OAE Analysis
- Examine/compare feature for DP-DP, TE-DP and TE-TE
- Full cross correlation, frequency analysis with reproducibility and signal-to-noise data on single test or between test pairs
- Full spectrum display during DP test shows higher order DPs
- Waveform analysis with response subtraction
- Detailed TEOAE spectrum analysis (50Hz resolution).
- Half-octave OAE power assessment
- Full numerical OAE data table provided
APPLICATION
APPLICATION
Echoport 292 I
Echoport 292 I
The powerful Echoport 292-I satisfies the most demanding of clinical needs. Providing a range of Gold Standard clinical OAE tests TEOAE, DPOAE, SOAE, DP Growth.
Echoport 292 II
Echoport 292 II
The Echoport 292 II dual probe delivers all the power of the Echoport 292 I and adds bilateral TE&DP recording plus Contralateral Suppression
DPOAE RECORDING
DPOAE RECORDING
- High resolution DPgram up to 8 points per octave (27 frequencies shown)
- Preset and customisable stimuli
- Programmable L1 and L2 level, frequency ratio, points/octave, frequency range, manual/automatic/intelligent frequency progression
- Total DP power assessment
- DP I/O growth rate analysis, dB/dB or scissor optimized stimuli
- Simultaneous binaural recording (ILO292-II only)
- True time domain averaging and noise statistics
- Ultra secure SNR assessment
- Total DP power assessment
TEOAE RECORDING
TEOAE RECORDING
- TEQuick Screen,non-linear, linear, tone pip and Standard ‘ILO’ (20ms) diagnostic recording
- Click stimulus or configurable tone pulse
- Configurable stimulus intensity. In-the-ear calibration
- Real-time stimulus and probe fit monitoring
- ‘ILO’ analysis giving OAE dBSPL and reproducibility in half-octave bands plus stimulus and response waveforms
- Simultaneous binaural recording (ILO292-II only)
ILOv6 Advanced Data Management and Analysis Software
ILOv6 Advanced Data Management and Analysis Software
- Fully searchable patient database with printable reports
- ILO standard DTA and DPG files
- Exportable data to OZ, Hi*Track, XML, ILOV5, Excel and ASCII (user selectable data elements)
- Import of data from other V6, Otolink or Ez-screen sites
- Integration of data from multiple sites, testers and machines
- Ability to run from a network and with a network database
ECHOPORT DESIGN
ECHOPORT DESIGN
- Robust, compact format
- USB plug-n-play connection to PC
- Lightweight and battery-free (powered by USB connection)
- Windows 10, 8 and 7 compatible
3 YEAR STANDARD WARRANTY:Included
3 YEAR STANDARD WARRANTY:Included
3 year instrument warranty is provided with all Echoports. Additional warranty is available if required ask for details
EASY FIT PROBE DESIGN
EASY FIT PROBE DESIGN
Otodynamics was the first with a right angled probe, designed to be small, light weight and easy to fit to help achieve a good probe fit. Find out about longer probe life
Testimonials
97.84% of our customers gave Otodynamics customer support 5 out of 5 and reported that they have 'very positive' experience
Surveyed 185 customers
Accessories Included
Specification Table
SPEC | DPOAE | TEOAE |
TEST CONFIGURABILITY | 4 Protocols, 14 Parameters | 4 Protocols, 10 Parameters |
FREQ RANGE (kHz) | 0.8 to 10.5 kHz | 1 to 6 kHz, 100 pts |
FREQ. RESOLUTION | 1,2,3,4,8 pts/octave | 50Hz, 80Hz or 1/2 octave |
FREQ RATIO | 1.04 to 1.5 (Δ0.02) | - |
STIMULUS LEVELS (dBSPL) | 40 to 80 (Δ1dB) | 40 to 90 (Δ1db) |
PASS CRITERIA | 10 Parameters | 10 Parameters |
PASS SNR | 1 to 14dB per 1/2 octave (Δ1dB) | 1 to 14dB per 1/2 octave (Δ1dB) |